Laboratory Equipment Measuring Instruments Scanner All in One Printer Card Reader. Page 28 SpectraMax iD3 Multi-Mode Microplate Reader User Guide 4. SpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. When combined with the SpectraDrop Micro-Volume Microplate, the reader can quantitate up to 64 samples with as little as 2 µL sample volume in a. for the SpectraMax M3/M4 and FlexStation® 3 Multi-Mode Microplate Readers. Multi-Mode Reader. For a higher . Each sample has a discrete sample beam and reference beam so. The introduction of the Molecular Devices’ SPECTRAmax PLUS microplate spectrophotometer marks the first time that photometric measurements made in a microplate format can be automatically normalized such that the resultant values are identical to those obtained with the corresponding solutions in a standard 1 cm pathlength cuvette. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. Contains one microplate adapter, five 24-well low volume slides, five 64-well low volume bottom slides, and five of each cover slide (2 µL and 4 µL) 0200-6267. Published Dec 16, 2020 | Updated Dec 16, 2020. Since the urine corticosterone ELISA is a competitive ELISA, absorbances were transformed into % Bound (B/B 0) for all samples using Maximum Binding (B 0) controls. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. 8: 0. 8 in. for ValitaTiter Assays. fl VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. The SpectraMax® iD3 and iD5 Multi-Mode Microplate Readers measure absorbance, fluorescence, and luminescence. 滤光片型光吸收微孔板读板机(酶标仪),简单易用,性价比高,检测结果精确. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. The basic problem caused by stray light (light you don't want, getting into the read) is a falsely low OD seen at the wavelength range of the band where you failed and at higher ODs. 313 reference gain check fail. Windows 11 compatible Windows 10 compatible Check compatibility; Version 7. Italic and boldface type are used for emphasis. G1–G3. The value for 1000 should be higher than the value for 900. SPECTRAmax PLUS 384 Microplate Spectrophotometer Operator’s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax PLUS 384 control panel are shown in boxed Helvetica type. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- The SpectraMax iD3 reader is built on the same foundation that has made our entire SpectraMax microplate reader product line among the most trusted in the industry. The SpectraMax® M3 Multi-Mode Microplate Reader dual monochromatic optics allows the widest range of applications to be utilized for bioresearch applications all without the need to change filters, and provides three modes of detection in one platform. 3) At the bottom of the strip, click on "Show. Narrow your selection of used microplate readers using the filters above or select the one of the categories on the left to view multi-mode or. H1–H3: Set up assay plate . 996 (n = 3) ; for SpectraMax Plus 384 reader, r 2 = 0. The Molecular Devices Gemini XPS Fluorescent Microplate Reader provides an ideal environment to determine the optimal excitation and emission settings for most fluorescent assays. VersaMax™ SpectraMax® 190. 2 GxP Software Suite from Molecular Devices. Method 66DNA Analysis on the Molecular Devices Spectramax Plus and Spectramax 190 microplate readers Quick Reference Guide Section A: Plate Materials A UV transparent microplate is required for. The Spectramax 190 has an array of data collection modes, including kinetic, endpoint, and spectral scan modes. 1 Version 7. #3635 or Greiner cat. Molecular Devices SpectraMax 190 User Manual (55 pages) Microplate Spectrophotometers. Prepare your i3/i3x instrument for shipment. Microplate Spectrophotometers. 7°C and the bottom to 36. 7°C (gradient heating design). Clear Filters. Read One Sample Or Up To 384 In A Single Plate Read Using Any Standard Cuvette, Or 96- Or 384-well Microplate. View the LabX ads below to find Molecular Devices SpectraMAX plate readers for sale and auction. 验证检测 SpectraMax 190 的工作状态。 堆板机、机械臂一体化整合 SpectraMax 190 可以在几分钟内整合到 Molecular Devices 的 StakMax 堆板机上。为了实现更高程度的自动化,自动化供应商 合作伙伴已经把我们的酶标仪系统和所有主要合作伙伴的机械臂 进行了整合。 STAKMAX. Some of the unique features of the SpectraMax Plus 384 Microplate Reader are: Wavelength Range: 190–1000 nm in 1-nm incrementsWe would like to show you a description here but the site won’t allow us. Add to Cart. 5. SpectraMax® iD5 Multi-Mode Microplate Reader - Five-Mode Hybrid Microplate Reader with Automatic NFC Filter Identification and Western Blot Capability, Molecular Devices. Brand: Molecular Devices |. SoftMax Pro. Trilevel commercial control reagents (StanbioOptical absorbance was measured at 734 nm on a SpectraMax M5 microplate reader. 100 readings per well gives optimal Z’ values for this assay. . The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm - 850 nm). The SPECTRAmax™ PLUS 384 microplate spectrophotometer provides rapid and sensitive UV/VIS measurements of a variety of analytes including specific proteins, nucleic acids, and other molecules across a wide range of concentrations. The proteins I examine with biuret assay are about 190_260 mg/ml that I dilute 40 times before the reagent addition. . The absorbance was then recorded at 535 nm using a SpectraMax 190 Microplate Reader (Molecular Devices) and iron concentrations were calculated from a standard curve. This kit is optimized for Molecular Devices SpectraMax microplate readers with a preconfigured protocol provided in SoftMax Pro Software for simplified data acquisition and analysis. Ship Ready. Example: [Drawer]. For customers outside the U. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5eMicroplate Reader, For Lab. 00 . In addition, SoftMax Pro Software SoftMax® Pro Software is the most published microplate reader control and data analysis software in the industry. The 4 injector configuration enables flash and glow BRET assays and a 2-fold improvement in speed for traditional flash and glow assays. SpectraMax® 340PC384 Microplate Reader for. Performance Specifications . 316 grating motor driver faulty. Molecular Devices Spectramax 190 Microplate Reader Biotek PowerWave XS Microplate Reader Our. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details. Clamp for injector 1 is on the left and clamp for injector 2 is on the right. The SpectraMax iD3 reader is a stand-alone multi-mode microplate reader that introduces NFC based user authentication and touchscreen interface personalization. Molecular Devices SpectraMax 384 Plus Microplate Reader Specifications. Usage/Application: Lab. Add to Cart. 313 reference gain check fail. Tailored to your different needs, these assay kits are configured and optimized for Molecular Devices SpectraMax® microplate readers, with preconfigured protocols provided in SoftMax® Pro Software for. The SpectraMax® absorbance spectrophotometers and plate readers provide the versatility and convenience for a wide range of assays such as ELISAs, nucleic acid and protein quantitation, and microbial growth. degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. SpectraMax 190 Absorbance Microplate Reader with laptop and software Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the. The absorbance of the resulting solution was measured at 540 nm using a SpectraMax 190 Microplate Reader (Molecular Devices, Sunnyvale, CA, USA), and analysed against the grape standard curve. The VersaMax and SpectraMax 190 read 96-well microplates. ValitaTiter Assays Setup Guide 2601A October 2023. 00 shipping. Figure 6: Transcreener ADP2 FI assay principle. 470 nm). Wide range of applications The VersaMax reader covers. . 발광 (Luminescence) 리더기. SpectraMax and VersaMax Plate Readers OperatorÕs Manual Ñ 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. 2. Page 1 SpectraMax M3, M4, M5, and M5 ® Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010. For a higher . degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. Microplate readers detect and process biological and chemical data using absorbance (ELISAs, enzyme activity, and nucleic acid and protein quantification), luminescence, and fluorescence detection modes, including intensity, TRF, and polarization. Designed to provide the simplicity, flexibility and power required for advanced data analysis. 2 release notes; Request software installer; ScreenWorks®. The drawing shows a standard microplate of 15 mm height covered with a lid. ** The SpectraTest ABS1 Absorbance Validation Plate will be discontinued on December 29, 2023. Expanded read mode capabilities Equipped for high performance, the SpectraMax iD5 is HTRF®-certified, DLReady, and SpectraMax® DuoLuc™certified. wells in a microplate (all instruments) or individual cuvettes (using SpectraMax Plus, Plus384, M2, M2e, M5e or M5 readers). The SpectraMax Injector System with SmartInject™ Technology features low dead volume (10 pL), overflow protection, and ensures. + details. 2. Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Molecular Devices의 Microplate Reader 및 washer와 원활하게 호환되는 강력한 벤치탑 Microplate stacker입니다. The patented multichannel optical design of the SpectraMax 190 Absorbance. Perkin Elmer Wallac Victor2 1420 Multilabel CounterMolecular Devices SpectraMAX 190 Microplate Reader/Spectrophotometer, Tested. Ultraviolet transparent multiwell plates from Greiner; Highly recommended for measurements of DNA and protein concentrations at 260 nm or 280 nm, respectively;Figure 1. Furthermore, VersaMax system is reliable, which means more uptime and lower long-term cost of ownership. com. Microplate reader assays requiring infrared (IR) or red-shifted assays can be read with great sensitivity using the iD5 reader’s filter system. This is equivalent to having 511 built-in filters, Plate chamber design of the SpectraMax category 1 microplate readers. The multi-channel design truly mimics a dual-beam spectrophotometer. 0 nm. wavelength and the ABS Plus reader ranges from 190-1000 nm, which is equivalent to having 510 or 810 free filters, respectively. The SpectraMax® Mini Multi-Mode Microplate Reader offers a budget friendly solution that gives you exactly what you need when you need it. begin reading microplates with seven mouse clicks. 2600A October 2023. Other technologies such as imaging. ” 312 gain calibration failed. 1 (Molecular Devices). The VersaMax and SpectraMax 190 read 96-well microplates. The SpectraMax® i3x Multi-Mode microplate reader measures spectral- based Absorbance, Fluorescence, and Luminescence on microplates that range from 6 to 384 wells. Examples: “Press carefully to engage,” “ Do not. 1 is GxP edition only; Protocols for the ABS1 Validation Plate. Wavelength (s) 200 to 1000 nm (Abs); 250 to 850 nm (Fluor); 250 to 850 nm (TRF) Microplate Data Acquisition and Analysis Software, users are now able to extend the ease-of-use of their typical plate reader applications to cell-based imaging and western blot detection. Also refer to this Multimode Reader Comparison Chart . Optional enhancements • SpectraMax MiniMax Imaging Cytometer • ScanLater Western Blot System • SpectraDrop™ Micro-Volume MicroplateThe Gemini XPS Reader can be integrated with Molecular Devices’ StakMax® Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. With optimized reagents and the industry-leading data acquisition and analysis tool, SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. 0200-6263. For more sample throughput, the system can• SpectraMax® 190 (Serial#-NNR-xxxxx) •ersaMax™ (Serial#-BNR-xxxxx) V • AquaMax® Microplate Washer. Examples: “Press carefully to engage,” “ Do not. 사용이 편리하고 견고한 생명과학 연구, 신약 개발, 개발, Bioassay용 assay. What plates do you recommend for SpectraMax Plate Readers? Luminescence: Solid white plates for top reads and white plates with clear bottoms for bottom reads. (volume is not critical because water does not absorb light appreciably between 190 and 900 nm) and read the plate. Molecular Devices Spectra Max Gemini Microplate Spectrophotometer. ISM Equipment Classification (Group 1, Class A) This equipment is designated as. Microplate Capacity. Urine corticosterone concentrations (ng/mL) were. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes. for the SpectraMax Multi-Mode Microp late Reader, as well as all other Molecular Devices' microplate readers. On LabX buyers can find. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-Analytical Technologies Group specializes in the maintenance and repair of Molecular Devices microplate readers, including the SpectraMax® and VersaMax™ absorbance readers. Read absorbance on the SpectraMax microplate reader at the wavelength to be used for your assay, and average the resulting OD values for all wells to obtain the Plate Background OD. For a higher . 2; SpectraMax ABS SpectraTest ABS1v2 712. 190. Features. The fluorometric performance of the SpectraMax M2e is similar, but slightly superior to that of the Gemini EM, a dedicated top and bottom read fluorescence microplate reader. SpectraMax ® M2 Multi-Mode Microplate Reader. 200. SpectraDrop Micro-Volume Refills, 24-Well Bottom Slides. M2. Beam Diameter Range (mm) Location of focal region in well. The multichannel design for 96-well microplates uses separate sample and reference beams for each. Compact and tunable absorbance microplate readers DATA SHEET. , Sunnyvale, CA). assay. In . As a generous estimate, you might consider 300 W (at 120 Volts) per Spectramax reader, plus another 300 W for the Computer. ” Molecular Devices 340PC384 SpectraMax Microplate Reader 7-XX7-58070-AB. すべてのSpectraMax® Mシリーズマルチモードマイクロプレートリーダーで、マイクロプレートおよびキュベットを使用して、紫外光・可視光吸光度ならびに蛍光強度を測定できます。. Free shipping. Measuring platelet aggregation with a microplate reader. SpectraMax190,340PC384,Plus384,VersaMaxMicroplateSpectrophotometersUserGuide 8 0112-0126D ComputerIntegration. + details. H1–H3. keeping with best practices, reader performance should. Temperature control and shaking come standard. The SpectraMax® ABS Plus Microplate Reader can run . book Page 1 Wednesday, October 12, 2011 4:56 PM The SpectraMax ABS Plus Microplate Reader is a compact and adaptive microplate reader capable of quantitating nucleic acid and protein samples in various formats such as cuvettes or microplates. Learn how to operate the VersaMax, SpectraMax 340PC384 and SpectraMax 190 Plus384 microplate readers, which offer fast and accurate absorbance measurements for a variety of assays. Setup Guide. Each sample has a discrete sample beam and reference beam so that each well is measured directly. 190: G1–G3. $500. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. SoftMax Pro can collect data from one or more microplates or cuvettes and store it in a single data file, using the same or different instrument settings for different microplates orSPECTRAmax PLUS Microplate Spectrophotometer Operator’s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax PLUS control panel are shown in boxed Helvetica type. With optimized reagents and the industry leading data acquisition and analysis tool, SoftMax® Pro 7 Software, the SpectraMax to perfectly match your needs. . For the calculation of the ratiometric biosensor signal, the emission intensity at 510 nm was recorded upon an excitation at 380 nm and 470 nm and the former was divided by the latter (Exc. KWIPPED is an online marketplace where businesses can rent, finance or buy all kinds of equipment from a large network of premier suppliers and equipment finance companies. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. Wavelength Range. Read one sample or up to 384. Example: [Drawer]. Additionally, the SpectraMax 190 Microplate Reader can be seamlessly integrated with the StakMax® Micropate Handling System through the SoftMax Pro. ABTS radical scavenging assayThe reading was performed in a spectrometer (SpectraMax 190, Microplate reader, Molecular Devices, USA) at 734 nm. The cycle is then repeated indefinitely until the shaking stops. About KWIPPED. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-Supplier: Molecular Devices. Spectral Range. Examples: fiPress carefully to engage,fl fiDo not press down. Chirag Patel, a graduate student at Johns Hopkins, reviewed Molecular Devices' SpectraMax M5 Multi-Mode Microplate Reader and found it an excellent resource for his lab's research on mTOR signaling in CD8 T cells. FlexStation® reader or a StakMax® microplate handler are advised to use a computer system that exceeds the recommended requirements due to the additional cache, processor, and RAM needs for these special-use cases. Using an SpectraMax Microplate Reader for DNA absorbance test, there is one. With three modes of detection for UV-Vis absorbance, fluorescence and luminescence, the SpectraMax Mini reader is user upgradeable - from 2 to 3 modes, providing researchers with a versatile. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. The patented multichannel optical design of the SpectraMax 190. The stained cells were solubilized in 95% ethanol for 20 min, and absorbance was measured at 590 nm with a Spectramax 190 microplate reader (Molecular Devices, Sunnyvale, CA, USA) with 14 biological replicates. Spectranet customer portal0112-0115 F 7 Description 1 Introduction The SpectraMax ® M3, M4, M5, and M5 e Microplate Readers are a series of dual-monochromator, multidetection, multi-mode instruments with a triple-mode cuvette port and 6-well to 384-well microplate readingFlexStation® 3 Multi-Mode Microplate Readers . Molecular Devices SpectraMax 340PC Microplate Spectrophotometer $ 3,500. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. Devices’ StakMax® Microplate Stacker in a matter of minutes and . Electrophoresis, Microplate Readers Lonza 384 Nucleofector System. Set up assay plate . 0112-0115J 9 Chapter1:Introduction TheSpectraMax®M3Multi-ModeMicroplateReader,SpectraMax®M4Multi-ModeMicroplate Reader,SpectraMax®M5Multi-ModeMicroplateReader,andSpectraMax®M5eMulti-ModeEvery SpectraMax® 340 PC 384 microplate reader has an optical system built around a monochromator. Vision Plate 96. 25ƒš (31. com. The multi-channel design truly mimics a dual-beam spectrophotometer. Examples: fiPress carefully to engage,fl fiDo not press down. 8 Customer Reviews. Spectramax i3 manualSpectramax i3 manual Microplate spectramax i3x molecular biocompareSpectramax i3. See SpectraMax® Microplate Reader User Manual Download Page. Pre-owned. #730. SpectraMax 340PC384 Microplate Reader A versatile 96- and 384-well format absorbance reader let the monochromator tune to that exact wavelength. ) gap between the rear of the instrument and the wall. The SpectraMax® 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. The SpectraMax M5 Microplate Reader is the standard for UV/visible multi-mode reader absorbance, providing ultrafast, full spectral range detection for cuvettes, 96-, and 384-well microplates. The SpectraMax® Plus 384 Microplate Reader from Molecular Devices can run both standard spectrophotometer and microplate reader applications on the same instrument. , call 1-800-635-5577. The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors. Both microplate and cuvette ports can be qualified. . The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors through the usage of a dual fiber optic exposure. 양한 다음 완전히 녹인 후, SpectraMAX 190 Microplate Reader 를 이용하여 405 nm에서 흡광도를 측정하였다. Simplify and expedite experiments with SoftMax Pro Software’s. For more sample throughput, the system canEquipped for high performance, the SpectraMax iD5 is HTRF®-certified, DLReady, and SpectraMax® DuoLuc™-certified. The SpectraMax M5 Microplate Reader possesses the five modes preferred by the majority of our users providing the benefit of multiple detection modes in one platform. Operational. Microplate Data Acquisition and Analysis Software, users are now able to extend the ease-of-use of their typical plate reader applications to cell-based imaging and western blot detection. SpectraMax® 340PC384. 190: G1–G3. 6-384 (96- and 384-well with pipetting) 6-384. 2 Version 7. Add to Cart. Customer Satisfaction is our number one goal All lab equipment in stock already tested and ships in 1-3 days Microplate Readers. Add to cart. Molecular Devices SpectraMax 340PC Microplate Spectrophotometer $ 3,500. Molecular Devices Spectramax 190 Absorbance Microplate Reader. Eight differentGet absorbance measurements from 190 to 1000 nm quickly for samples in test tubes, cuvettes, and 96- or 384-well microplates. Using the patented PathCheck® Pathlength Measurement Technology, the SpectraMax. SpectraMax L Microplate Reader is a sensitive luminometer with programmable injector options that measures flash and glow luminescence assays, including dual luciferase reporter gene, G protein-coupled receptor (GPCR) in 96- and 384-well plates. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Molecular Devices SpectraMax ABS Plus Absorbance Microplate Reader. The SpectraMax L reader is available in 1- and 2-channel (Photomultiplier Tube) configurations. It offers the additional advantage of HTRF ® (homogeneous time-resolved fluorescence) certification, allowing. Please refer to the Obsolete Microplate Reader Models for more information. Operational temperature 18ƒšº to 40ƒš°C. When the user applies a set temperature of 37°C, the top is heated to 37. spectramax ABS microplate readers, spectramax ABS plus microplate readers, spectramax ABS readers, ABS plus microplate readers, ABS microplate readers, spectramax ABS plus reader. Streamline GLP/GMP compliance. A microplate reader that can detect two or more applications is considered a multi-mode plate reader. For a higher . 304 signal level saturation. Microplate reader assays requiring infrared (IR) or red-shifted assays can be read with great sensitivity using the iD5 reader’s filter system. Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. It provides ready-to-run protocols, analysis algorithms, and 21 different curve fit options. SoftMax® Pro 7. Example: [Setup]. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. 6-384. Molecular Devices SpectraMax M2 Microplate Reader w/ Softmax Software and PC. When the user applies a set temperature of 37°C, the top is heated to 37. Examples: fiPress carefully to engage,fl fiDo not press down. the absorbance was measured at 517 nm using a microplate reader (SpectraMax 190, Molecular Devices, USA). Read one sample or up to 384 in a single plate read using any standard cuvette, 12 x 75 mm test tube, or 96- or 384-well microplate. Microplate reader assays requiring infrared (IR) or red-shifted. unconventional microplate reader assays, including imaging cytometry and western blots • Protocol sharing with a strong user community • Spectral optimization wizard to maximize assay signal window (SpectraMax i3x and Paradigm readers only) SoftMax Pro Software SoftMax Pro® Software is the most publishedAfter incubation, the supernatant was carefully eliminated, and attached bacterial cells were stained with 0. For more detailed information and technical support of Life Technologies assays, please call 1-800-955- 6288 and enter extension 40266 or email [email protected]. Fluorescence Microplate Reader Comparison Chart. The wavelength and scanning ranges are from 340–850 nm in 1 nm increments. Plate Reader. Statistical analysis. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. The SpectraMax® M5 Multi-Mode Microplate Reader delivers single mode reader performance and can be equipped to read volumes as low as 2uL in one multimode reader package. used. The results were expressed as percentage of inhibition calculated by Eq. MultiLabel Plate Reader. Description Control Panel Cuvette Chamber Back Panel Microplate Drawer The Control Panel TEMP on/off TEMP Figure 1. The VersaMax and SpectraMax 190 read 96-well microplates. Offer Ends In: 43 Days 20: 23: 11. Microplate Readers Biotek ELx808 Microplate Reader. In addition, SoftMax Pro Software Volume is not critical because water does not absorb light appreciably between 190 and 900 nm. Category 2 and 3 microplate readers use gradient heating as well. If no values are present, the water constant values are missing from the NVRAM. SPECTRAmax® 190. SpectraMax Glo Steady-Luc Reporter Assay Kit workflow. The optical system of the SpectraMax 190 Microplate Reader is built around a monochromator, which allows for selection of up to six wavelengths at a time for absorbance detection in the UV-visible wavelength range (190 nm – 850 nm). Microplate readers use a vertical light path so the distance of the light through the sample depends on the volume. 3) This. On LabX buyers can find a variety of SpectraMAX models for sale: 190, 384, 340 and the SpectraMAX M series. Instrument settings can be saved as a protocol file and used repeatedly for reading different microplates or cuvettes. The contents of. The narrow bandwidth provides greater measurement accuracy and linearity over the widest assay range, including DNA. This user guide provides detailed instructions on how to operate, maintain, and troubleshoot the device, as well as examples of applications and. Widen the range of quantitative experiments with a 190-1000 nm wavelength range. 0 nm. 306 plate air cal fail,low light. Molecular Devices Skantron SkanWasher 400. Fluorescence was measured on a SpectraMax M5 microplate reader. The SpectraMax Plus 384 Microplate Spectrophotometer is a versatile and reliable instrument that can measure absorbance in the UV and visible range. Example: [Drawer]. These lab workhorses are used in drug discovery, research, bioassay validation, and. 67. 75 mm) high. These robust readers have been placed in labs from. The SPECTRAmax 190 can accommodate standard 96-well microplates, strip wells, and Þlter-bottom microplates. UV Qualification, using NIST traceable standards, is now available for SpectraMax 190, Plus 384 and the M Series (M2/M3/M4/M5/M5e) Parameters that are checked during the UV Qualification are: Wavelength accuracy. + details. The SpectraMax® 190 can read as low as 2μL with the μMax Low Volume Plate. 1) Select the correct plate and the wells that you want to measure. This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. . 00. ₹ 1,80,000 Get Latest Price. SoftMax Pro Software is an industry-leading acquisition and analysis software with over 160 ready-to-run protocols, powerful data analysis, and a range of data output options. Supplier: Molecular Devices. SpectraMax ABS PLUS Microplate Reader with UV-Vis and Cuvette SpectraMax ABS Microplate Reader Photometric performance Wavelength range 190 nm – 1000 nm 340 nm – 850 nm Wavelength selection Monochromator, tunable in 1. SoftMax Pro. iD5. So the impact is usually on linearity and the measured absorbance will be lower than the true absorbance. Introduction. 8. The SpectraMax ® M5e Multi-Mode Microplate Reader is a dualmonochromator capable of fluorescence, time-resolved fluorescence (TRF), fluorescence polarization, absorbance, and luminescence assays. Camptothecin (8mM) and fibroblast growth fac-tor (FGF; 20nmol/L) were used as negative and positive controls, respectively. 00 . The PMT gain can be set to manual, high, medium, low, or automatic (Figure 3A). Molecular Devices SpectraMax 384 Plus Microplate Reader. Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089. 제품. 190 – 1000 nm: Wavelength Selection: Monochromator, turnable in 1. Windows 11 compatible Windows 10 compatible Check compatibility; Version 7. Page 6 SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Connecting Instrument Cables The power cord and USB cable connect to the ports on the rear of the instrument. SPECTRAmax 190. SoftMax® Pro Microplate Data Acquisition and Analysis Software Version 6 User Guide 5014177 C October 2011 FrameMaker_Export. Reader spectramax microplate id3 molecular devices multi mode boundaries functionality instrumentSpectramax i3x multi-mode microplate reader with minimax imaging Molecular devices spectramax i3x 使用される. Microplate Reader. Photometric accuracy. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax ® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user. Environment. The plate reader optics are tunable for absorbance, fluorescence intensity, fluorescence polarization, and time resolved fluorescence assays (TRF). 0: 200. Learn how to set up protocols, customize reports, export results, and more with this PDF document. The plate reader can measure multiple readouts, including UV. Type: Clear: Add to Cart. Data were normalized for total protein/well. In addition, the iD5 reader measures TRF and FP and can be expanded to include TR-FRET, HTRF®, BRET, dual luciferase reporter assays with injectors, and western blot detection.